Start with activities and preferences
Mobility, fatigue, reach, sight, hearing and sensory choices belong in the discussion. A diagnosis does not describe a layout.
Describe what worksStart with the person
Trace a working day with the person who’ll use the office, from unlocking the door to reaching the desk and getting home. Use the two furniture layouts to test what needs to change.

At a glance
Mobility, fatigue, reach, sight, hearing and sensory choices belong in the discussion. A diagnosis does not describe a layout.
Describe what worksA cabinet can clear the final open leaf yet block the door during its swing. Static furniture bounds tell only part of the story.
Inspect the worked examplesUsable opening, floor levels, weathering and personal operation need the selected drawings and user-specific review.
List the missing evidenceGo through each part of the day with the person who’ll use the wheelchair-accessible office: reach it from the house, unlock and open it, enter, work, use storage, leave and return. A supplier’s accessible label or a generous floor-area total does not establish that whole sequence for a particular person.
Limited mobility is broader than wheelchair use. Walking with an aid, carrying a laptop, gripping a handle, standing to unlock a door or making the return journey when tired can each change the brief. Ask about rest and assistance without assuming either is wanted or needed.
Discuss the actual aid or device configuration, changes through the day, carrying, turning and any companion. Review both outward and return trips, including after dark or in the weather the person expects to use the office.
Include locks, switches, window controls, plugs, desk adjustment and frequently used storage. Record grip, effort, posture and fatigue during the activity, rather than assigning a universal height or reach distance.
Try controllable lighting and shading, consider reflections and ask how easily controls and edges can be identified. RNIB’s workplace advice stresses personal lighting preferences and warns against assumptions based on an eye condition. Brighter or dimmer is not automatically better.
Discuss noise, temperature, smells, visual complexity, predictable controls and preferred communication. The National Autistic Society explains that an adjustment helpful to one person can be unhelpful to another. Treat these as choices to explore, not a fixed sensory-friendly palette.
For an employee, HSE’s workplace-adjustment guidance supports discussion with the worker, review when circumstances change and specialist input where needed. It also addresses consent and the person’s choice about disability details. This brief has no diagnosis field: record the practical information the person wants to share and needs for the design.
A desk layout begins with the work and the occupied position, not just the top’s width. Obtain the actual underside height, knee and toe space, support and crossbar locations, adjustment range, controls and cable positions. Check screens, papers and other equipment in use, plus storage while it is open. A footprint cannot establish any of those relationships.
For wheelchair turning space, device width alone is insufficient. The person’s position, footrests, propulsion or controls, turning behaviour and any assistance all matter, along with the door and furniture states. Our examples deliberately do not substitute a generic wheelchair outline or turning circle for that information.
Both original drawings use an invented 3.60 × 3.00 m finished internal room, giving 10.80 m² of enclosed geometry. A keeps storage near the entrance; B rotates and moves the same cabinet towards the top wall. These are furniture-operation studies with a visible trade-off, not completed accessible designs.
A. Storage blocks the swing. The cabinet body and extended drawer overlap the swept sector, even though they miss the final fully open leaf.
B. Move storage, then reassess. Moving and rotating the same cabinet removes that collision. Storage now sits below the proposed glazing in plan; reach, opening approach and window operation need review.
Neither view establishes an occupied route, turning space or personal fit. The complete assumptions and both detailed plans follow.
The door cannot complete this illustrated swing through the occupied cabinet position. Checking only the final fully open leaf would miss the collision. The drawer adds another operated state to check, even though the cabinet’s stationary bounds lie inside the room.
B increases the empty measurement at one horizontal section by 1.25 m. It does not add floor area or prove a usable journey. Storage reach and opening approach have changed, while the proposed window introduces a vertical coordination question that a plan cannot answer.
At y = 1.80 m, A measures from the desk working edge at x = 0.95 to the extended drawer edge at x = 2.35: 1.40 m. B measures from the same desk edge to the right wall at x = 3.60: 2.65 m. They are unoccupied horizontal intervals at that section. Neither is a route width, turning allowance or recommended clearance.
The next drawing needs the person’s real occupied and operated states, not a guessed shaded zone. The HSE workstation checklist is useful for questions about equipment reach, chair adjustment, movement and reflections; it does not turn these illustrative dimensions into a personal fit result. Use the furniture guide to collect the actual equipment and opening dimensions.
Connect the interior to the actual outside route. A nominal leaf width or assembly size is different from the passage available when a door is in its usable open position. In England’s Approved Document M Volume 2, effective clear width accounts for the closing-side stop and hinge-side obstructions; its provisions vary with approach and building context. Do not borrow one figure as a universal garden-office opening.
Door operation also involves positioning, grip, force and the sequence of opening, passing through and closing. A sliding door has a different operation from a hinged leaf, but neither label proves it works for the person. Coordinate both approaches, the threshold, floor surfaces and the occupied interior.
A flush-looking photograph is not a construction section. Ask for the actual inside and outside finished levels, track or upstand, seals, cill and drainage together. Origin’s threshold guidance distinguishes weathered and non-weathered arrangements and says drainage is site-specific. Its named mobility threshold is described for Single and French doors; that wording should not be transferred to every bifold.
| Evidence | What must be resolved |
|---|---|
| Selected door drawing | Exact model and configuration, revision, opening direction, usable open state, leaf or assembly dimensions and any panel stack. |
| Effective opening and operation | Measured passage with stops, handles, seals and moving panels considered; approach, handle and lock actions, force and powered-operation failure behaviour if proposed. |
| One coordinated vertical section | Inside finished floor, outside finished surface, track or upstand, seals, cill and drainage paths, all using one level datum. |
| Actual floor and junctions | Floor build-up and covering, edges, joints and mats; rolling or walking experience and surface conditions with the intended user. |
| Weather and drainage evidence | Documentation for the exact selected door and installed combination, maintenance needs and who owns design and installation decisions. |
| Route, arrival and return | Both approaches, changes in level, lighting, rest and assistance where relevant; include the journey home and the intended exit arrangement. |
| Personal and professional review | What the user has actually tried and the appropriate access, occupational or building-design advice still needed; record both separately. |
Dore’s supplier case, dated 2 July 2026, reports a 4.5 × 3 m room with sliding doors and coordinated floor, threshold and drainage work. The published size has no confirmed internal or external basis here. It illustrates coordination; it does not supply your selected section or verify your access.
The New Garden Room Company’s Coventry case reports a 4 × 3 m project completed in October 2022, connecting house, garage and room for a powered-wheelchair user. Its reported route and ramp belong to that project. We have not inspected it or established a transferable gradient, usable opening or personal movement space.
Keep personal usability and applicable obligations as separate checks. Approved Document M is England guidance with separate dwelling and other-building volumes; the appropriate route depends on the actual building and use. Establish the nation and proposal with the responsible designer or authority. The permissions guide helps separate planning, building control and other permissions.
Develop the outside route, threshold and return-journey brief with the person using the room.
Plan the complete access routeUse this record to connect each activity to a preferred adjustment, an actual check and the evidence still needed. Keep the person involved in how the brief is written and shared. It can support a discussion with the supplier, access specialist, occupational adviser or building designer; it does not claim any of them have assessed this project.
| Field | What to record |
|---|---|
| Activity and what works | Drawing revision and date; intended tasks, working pattern and arrangements that already work for the person. Record: ____ |
| Barrier and preferred adjustment | Describe the experienced difficulty and the change the person would like to try; record preferences rather than a diagnosis. Record: ____ |
| Aid, device and assistance | Only information the person chooses and needs to record: actual equipment configuration, occupied bounds, footrests, controls and any companion or assistance space. Record: ____ |
| Desk and equipment states | Actual top and underneath dimensions, adjustment, supports, cables, screens and storage in stationary, occupied and operated states. Record: ____ |
| Reach, effort and fatigue | Observed reaching, grip, opening effort, posture, carrying, rest and return-journey needs; note what has not been tried. Record: ____ |
| Sensory and communication preferences | Light, glare, sound, smell, temperature, visual complexity, controls and communication choices; record preferred adjustments and working times. Record: ____ |
| Whole journey and entrance | House-to-room and return route; door actions, approach, effective opening, floor and threshold details, and a personal exit or assistance arrangement to resolve. Record: ____ |
| Safe trial record | What was tried, with whom, where and when; record what worked, difficulty, fatigue, assistance and untried states. Record: ____ |
| Unresolved evidence and owner | Missing drawing or user-specific advice, responsible designer or adviser, document reference and next action; no assumed approval. Record: ____ |
| Changes and review dates | What must be rechecked before manufacture, at installation and after use; include changes to equipment, circumstances or preferences. Record: ____ |
No actual user-specific design advice, personal movement test or selected door and floor detail has been supplied for these examples. Request the relevant advice and the exact drawings listed above, then record who resolves each outstanding point. General guidance and a blank checklist do not satisfy those missing project-specific facts.
The text file repeats all ten fields, both example layouts, the entrance evidence requests and review sequence. Complete and save your copy locally; downloading it sends no supplier enquiry. When the design and responsibilities are defined, use the quote-comparison guide to keep the same specified work in each proposal.
HSE adjustment guidance, RNIB, National Autistic Society, Origin and the official England Approved Document M landing page were checked on 21 November 2026. The clear-opening guidance and supplier examples refer to the documents and dates listed below. The two example layouts use fictional dimensions for the room, furniture, drawers and doors. No personal design advice, occupied user trial or selected door/floor detail has been obtained. Check the route, doorway and controls with the person who will use them and record what the supplier still needs to confirm.