Compare the complete assemblies

Garden room thermal details

A wall’s U-value tells you about just one part of the room. Ask each supplier for figures for the finished walls, roof, floor and windows, and for drawings showing how they join.

Sources checked 21 November 2026

The wall, window and floor meet beside a desk in a garden room.

Compare complete wall, floor and roof assemblies

What to record for each wall, roof or floor

Ask for details at the wall, roof or ceiling, floor, and openings. Use the same drawing revision and comparable whole-assembly data.

A U-value measures heat flow through one square metre of a stated element for each degree of temperature difference, in W/(m²·K). See Rushcliffe Borough Council’s U-value explanation. Put the figure beside the component or full assembly it covers. A wall’s figure covers one part of the room. Windows, roof, floor, junctions and air movement also influence heat loss.

SIP and lined timber-frame assemblies

  • SIP-based assembly. Ask what the selected panel, connections, finish and surrounding assemblies contribute.
  • Lined timber frame. Ask for the framing, insulation, lining and continuity around the structural paths.
Ask for the same evidence in both assemblies
FunctionSIP-basedLined timber frame
StructureAsk for the selected panel facings, core, supported span and joints.Ask for selected studs, sheathing, support and connections.
ThermalAsk how the wall, roof and floor join and what the thermal figures cover.Ask how frame members, infill and other insulation enter the complete thermal figure.
Moisture, weather and airAsk for sill and base details, joints and seals, and separate occupant ventilation.Ask how moisture and air control connect at the base, roof and openings, with separate occupant ventilation.
See the SIP assembly diagram
Unscaled SIP room outline with a separate wall detail showing OSB facings, insulation core and the marked junction between panels.
The Kingspan TEK August 2023 brochure, page 3 identifies two 15 mm OSB/3 faces, a rigid urethane core and a proprietary insulated panel interface. The schematic marks the interface. Ask for the project’s selected joint and its continuity. Open the full-size diagram
See the lined timber-frame diagram
Unscaled timber-frame room outline with an excerpt showing sheathing, timber studs and mineral wool between the studs.
The BBA Tyvek Reflex certificate, Table 6 describes an example wall with a brick outer leaf, OSB sheathing, and a timber frame with mineral wool between the studs. The schematic shows the frame excerpt. Ask for the complete wall and how the studs and junctions enter the thermal assessment. Open the full-size diagram

Product example. On its GB page, Kingspan TEK lists 142 mm and 172 mm overall SIPs for walls and roofs. It describes I-beams or open web joists for intermediate floors. Record panel thickness, insulation depth and finished assembly depth in separate fields. Ask for the actual floor and roof/ceiling specifications for the chosen room.

Noah’s insulation guide describes a supplier’s assembly scopes. For an England project, ask the designer which provisions and edition of Approved Document L apply.

Compare glazing and openings

Request the whole-window or whole-door thermal data for the proposed size and frame. Compare solar gain, daylight and glare alongside heat loss, orientation and how the opening will be used. When comparing double and triple glazing, check the frames, seals and installation details too. If the figure covers only the glass, label it ‘glass only’ so you don’t compare it with a whole-window figure. Ask how the fitter treats the sill, frame edges and window openings, and make sure planned shade and desk layout work with opening and maintenance.

Energy Saving Trust’s windows guidance explains why the glass, frame and spacers all matter.

Coordinate airtightness and moisture control

Ask for the roles of the rain screen or masonry face, weather protection behind it, ground moisture detail, air and vapour control and deliberate occupant ventilation. A suitable breather membrane can help limit wind-driven liquid water reaching the structure while letting water vapour pass. Check the specific product and complete wall detail in the designer’s plan. See DuPont’s wall and floor technical manual. Occupants still need a deliberate fresh-air route. A vapour-control layer needs to work with the entire build-up and expected moisture, with a designer’s decisions for its position and continuity. If a draught appears, record where and when without blocking a designed vent. For an existing brick room or a new masonry option, ask how the base, walls and openings resist actual rain and ground moisture. A thermal bridge is a local path for greater heat flow, for example through a timber member that conducts more heat than the insulation beside it or where insulation is interrupted at a junction. Ask how the proposed details keep air and thermal layers continuous at the base, roof, door, window and penetrations, and how that will be checked before they close.

For different weather and air/vapour control roles, see DuPont’s product guidance. Ask how the selected details manage moisture alongside deliberate occupant ventilation. For England, Approved Document C gives context for site preparation and moisture protection.

What do the insulation figures cover?

Ask for the complete wall, roof and floor build-ups, the window specification and drawings of the junctions.

Open the private project planner

Sources and checks

The two drawings are unscaled sketches based on published wall examples, with room-envelope questions around each. Ask the project designer to verify the complete selected roof, floor, wall, base and opening details against matched drawings. Include thermal, structural and moisture review.

  1. Kingspan TEK Building System GB — Published overall SIP thicknesses for walls and roofs and separate intermediate floor system. Checked 21 November 2026.
  2. Noah insulation guide — Supplier example of wall, floor, roof and lining scope. Checked 21 November 2026.
  3. Energy Saving Trust windows and doors — Whole-window context including frame, glass and spacers. Checked 21 November 2026.
  4. DuPont Tyvek and AirGuard FAQs — Manufacturer descriptions of different weather, air and vapour roles. Checked 21 November 2026.
  5. Energy Saving Trust ventilation — Occupant ventilation as a separate matter alongside air leakage and moisture. Checked 21 November 2026.
  6. England Approved Document C — Moisture and site preparation scope in England. Checked 21 November 2026.
  7. England Approved Document L — Current editions and applicability by type and project. Checked 21 November 2026.
  8. Kingspan TEK self-build brochure, issue 14 (August 2023), page 3 — Named SIP’s two 15 mm OSB/3 facings, rigid urethane insulation and insulated jointing system. Checked 21 November 2026.
  9. BBA 90/2548 PS3 Issue 9, Table 6 — Named timber-frame wall example under a brick outer leaf, including OSB, mineral wool and timber bridging. Checked 21 November 2026.
  10. DuPont Walls and Floors Technical Manual — Weather resistance and water-vapour permeability as functions of a suitable breather membrane. Checked 21 November 2026.
  11. Rushcliffe Borough Council low-carbon design guidance — Definition of thermal transmittance per unit area and temperature difference. Checked 21 November 2026.