CONSTRUCTION SYSTEMS
How will the walls, floor and roof fit together?
Ask what carries the load and what each finished wall, floor and roof contains. Then find out which parts arrive assembled, who joins them on site and who finishes the room.

Compare declared assemblies
Ask for the actual wall, floor and roof build-up. The Kingspan TEK GB specification names its rigid urethane core and OSB/3 faces, with different intermediate-floor construction. Green Retreats’ timber construction information and U-Roof Bespoke 066 illustrate different scopes. U-Roof describes light-gauge galvanised steel and gives frame dimensions. Request drawings of the finished room and its supporting design.
Modular describes delivery or assembly, and a module can itself use a timber frame. First identify the wall, floor and roof construction. Then record whether it arrives as an assembled module, as factory-made panels or as parts to build on site. Compare access and handling, joints between delivered elements, the base interface and who finishes and connects the services.
Compare exterior dimensions after cladding, clear finished interior and full roof height after coverings. The gross footprint affects siting and the clear interior affects furniture. Frame dimensions alone leave both quantities open.
See the Structural Timber Association’s timber-frame roof/eaves diagram 2.3(a) and timber-frame floor-zone diagram 2.4(a). These show where a timber stud frame and the adjacent cladding can move differently. The 2008 details explain the junction principle. For the actual garden room ask the supplier to mark the frame, floor support, roof support and cladding movement on its own sections, with insulation continuity and moisture strategy shown separately. The Kingspan TEK specification and published 172 mm SIP details illustrate a different assembly.
Find the load-bearing studs, separate cavity insulation and structural sheathing in CS Architecture’s timber-stud wall section. The Frame Build UK ST-01-001 ground-floor detail labels the external panel, timber soleplate, damp-proof course and indicative floor support. In the linked Kingspan SIP detail, structural OSB faces are bonded around an insulated core. The U-Roof listing identifies a galvanised steel frame and describes when it supplies the order-specific drawings. Confirm actual dimensions, junctions and who verifies the offered system.
Assembly and performance comparison
Record delivery separately for every system. Record finished dimensions and request evidence for the whole assembly.
Download the assembly comparison worksheet
| Assembly | Actual model and revision | Dimension and datum | Evidence or drawing reference | Delivery and named owner | Outstanding |
|---|---|---|---|---|---|
| Timber stud frame | — | — | — | — | — |
| Structural insulated panel | — | — | — | — | — |
| Light-gauge steel frame | — | — | — | — | — |
| Other panel system | — | — | — | — | — |
The published Kingspan TEK 172 mm standard details illustrate junctions for that named system thickness. Compare them with the drawings for the offered assembly. Obtain the exact floor, wall, roof and opening details for each bid and ask who verifies the completed build-up on this site.
What supports the claims about heat loss, moisture and durability?
Ask for evidence covering the walls, floor and roof as they’ll be built, including where they meet. Ask about floor-to-wall and roof-to-wall continuity, window interfaces, structural capacity, moisture management and relevant fire performance. Generic panel specifications leave gaps at joints and finishes and may use a different build-up than your quote.
Durability concerns include keeping moisture away from vulnerable materials, protecting the intended finishes and being able to maintain or replace individual parts. Ask who is responsible for inspecting interfaces and documenting the as-built condition.
Identify site and assembly implications
If a quote mentions floor screws, confirm which job they do. Foundation ground screws reach into the ground as part of the support design. Floor-to-frame and board fixings belong to the designed assembly. Get the applicable foundation and fixing drawings and avoid assuming interchangeability.
Confirm where the installer needs access, what documents accompany the package and who checks the base datum and tolerances. A delay to review a drawing is easier to resolve before panels are delivered.
Evidence request
Ask the supplier and project designer to complete this for the quoted configuration.
Download the assembly evidence request
| Field | Your record |
|---|---|
| Drawings and revisions for the ordered build | — |
| Floor-to-wall, roof-to-wall and opening junctions | — |
| Assembly fire, thermal, moisture and structural evidence | — |
| Foundation schedule and separate frame or floor fixings | — |
| Delivery form and responsibility for joining, weatherproofing and service handover | — |
| Substitutions, designer and approval process | — |
| As-built evidence and maintenance access | — |
Related guides
Sources and checks
Published specifications apply to the named systems. The comparison points identify the evidence to request for the complete room and junctions.
- Kingspan GB TEK system composition — Kingspan GB TEK system composition Checked 21 November 2026.
- U-Roof Bespoke 066: steel-frame panel specification — steel-frame panel specification Checked 21 November 2026.
- Insulated Panel Store: Medio kit and frame distinction — Medio kit and frame distinction Checked 21 November 2026.
- Green Retreats insulated garden rooms — Green Retreats insulated garden rooms Checked 20 November 2026.
- DuPont Tyvek and AirGuard FAQs — DuPont Tyvek and AirGuard FAQs Checked 20 November 2026.
- Kingspan TEK 172 mm standard details, published by Norman Piette — Published Kingspan system examples for one panel thickness. Illustrations remain scoped to the standard assembly. Checked 21 November 2026.
- Structural Timber Association: platform timber frame movement, diagram 2.3(a) — Published timber-frame eaves example where a frame-backed roof meets masonry cladding. Checked 21 November 2026.
- Structural Timber Association: platform timber frame movement, diagram 2.4(a) — Published platform timber-frame floor interface with lightweight cladding. Movement-led example. Checked 21 November 2026.
- CS Architecture: typical clad timber-stud wall — Architect’s labelled timber-stud wall section, opened and independently verified in the evidence receipt. Checked 21 November 2026.