Planning and building control
Garden room planning in Wales
Measure from the proposed room to the house and to each boundary. Give those distances, the roof shape and the heights to your Welsh planning authority. Ask building control separately about the construction and services.

Check the Welsh planning route
Apply the two height bands to the parts they cover
Welsh Class E provides a route for qualifying purposes incidental to a dwellinghouse. Ask planning whether the property retains these rights and whether the intended use qualifies. Give the planned activity, visitors, services and any overnight use.
- Within 2 m of a boundary. Check the parts in the band against the 2.5 m height limit in E.1(f).
- Within 2 m of the house. Check the parts in this band against the 1.5 m height limit in E.1(h). At an overlap, apply both conditions.
- Roof and eaves. Mark the immediately adjoining ground for each affected part. Welsh Government guidance gives 2.5 m for flat roofs and 2.5 m for eaves. Ask planning which additional roof and eaves provisions govern your proposed roof, ground and proximity.
Check the principal elevation of the original house and any side elevation that affects proximity to a highway. Record the single-storey proposal, raised platforms and protected status. Listed-building curtilage is outside this Class E route. Designated land and World Heritage Sites have additional siting and coverage restrictions.
For E.1(a), divide ground covered by the qualifying buildings, enclosures, raised platforms, pools and containers by the total curtilage area after removing the original house footprint from both sides of the calculation. Check the result against the 50% limit and have planning confirm what belongs in each area. Welsh statutory Class E substitution · Welsh Government outbuildings guidance · Technical guide, section 11
Mark the two bands and adjoining ground
Check building control and services
Use the measured floor area and specification
Send building control the floor area, storeys, materials, distances, intended use, design and services. Schedule 2 Class 6 includes two relevant categories.
- Up to 15 m². Paragraph 3 covers a detached building with no sleeping accommodation, subject to the applicable exemption rules.
- Up to 30 m². Paragraph 1 covers a detached single-storey building with no sleeping accommodation where every point is at least 1 m from the curtilage boundary or construction is substantially non-combustible. Ask building control to assess the exact construction and site.
Regulation 9 can retain certain water requirements. For a Class 6 building receiving electricity from a source shared with or inside a dwelling, it retains Part P. Ask the electrician and building control which Welsh notification and certification route applies to the work. Building Regulations 2010, regulation 9 and Class 6 · Welsh outbuildings guidance · Welsh Approved Document P and amendments
What to show on your Welsh site plan
Send one measured drawing pack
Include the original house, proposed and existing works, ground levels, heights and roof type, internal floor area, property history, actual use, services and proposed certifiers. Ask the planning team and building control to reply separately in writing, each referring to the date on your drawing. Find your planning authority · Find a building control body
| Item | Your record |
|---|---|
| Property and use | Existing rights, house type, working, visitors, overnight use and drawing revision. |
| Plan and frontage | Original house, principal and side elevations, roads, curtilage and other works. |
| Distinct 2 m bands | Mark affected house and boundary portions and any overlap. |
| Height and ground | Roof form, eaves and height at each affected part from its adjoining ground. |
| Coverage calculation | Include qualifying existing and proposed work. Exclude the original house footprint. |
| Protection and other works | Listed or designated land, rights removal and balconies or raised platforms. |
| Building control | Floor area, storeys, sleeping, shortest boundary gap and construction materials. |
| Services and evidence | Electrics, supply origin, water and drainage. Record responsible trade and certification. |
| Named issue owners | Planning, building control, electrician, reviewer, scoped decision and follow-up date. |
Official source register
Keep the written replies from planning and building control with your drawing, including who answered each question.
Planning · Welsh Class E and outbuildings guidance
Check E.1(a) to (j), E.2 and E.5 for coverage, siting, heights, protected settings and the eaves definition. The local planning authority confirms property rights and applies the tests to the actual drawing. Welsh territorial substitution · Government checklist · Technical guide, section 11 (PDF)
Building control · Class 6 and regulation 9
Check Class 6 paragraphs 1 and 3 and retained water and power requirements in regulation 9. Give the measurements, materials and intended use to the building control body. Regulations · Welsh outbuildings guidance
Electrical work · Welsh Part P
The electrician and building control agree which safety, notification and certification requirements apply. Check the Welsh guidance and linked amendments. Welsh Approved Document P
Who to ask · Welsh authority directories
Planning authority for site rights and siting. Building control body for construction and services. Local planning authority · Building control body
Keep your written responses with the specification in the quote planner.
Related guides
Sources and checks
The Welsh Government’s outbuildings guidance and technical guide explain the Welsh Class E planning rules. Give your local planning authority the roof shape, heights and distances from the house and boundaries. Ask building control separately about the proposed construction and services.
- Welsh Class E territorial substitution — Schedule, Part 1, Class E identifies qualifying uses, E.1 siting and height tests and E.2 protected-area conditions. Checked 21 November 2026.
- Welsh Government planning permission for outbuildings — Summarises the separate house and boundary bands, flat roof and eaves checks, frontage and other limits. Checked 21 November 2026.
- Welsh Government householder technical guide (PDF) — Section 11 reproduces the Class E tests and explains the roof, eaves and immediately adjoining ground. Apply E.1(f) and E.1(h) separately. Checked 21 November 2026.
- Building Regulations 2010, regulation 9 and Schedule 2 Class 6 — Defines the no-sleeping small detached building categories and retained water and electrical requirements under regulation 9. Checked 21 November 2026.
- Welsh Government building regulations for outbuildings — Summarises common detached-building cases and the separate approvals question. Checked 21 November 2026.
- Welsh Approved Document P — Presents Welsh electrical safety guidance and its amendments. Checked 21 November 2026.
- Welsh local planning authority directory — Identifies the authority to ask about rights and measured drawings. Checked 21 November 2026.
- Welsh building control directory — Identifies local authorities and registered building control approvers. Checked 21 November 2026.