GARDEN OFFICE ENERGY-USE AND TARIFF WORKSHEET Date and period: Room, weather, openings and occupants: Provider, region, payment type and tariff date: COPY THIS SECTION FOR EACH DEVICE AND TIME BAND Device/model and function: Rated input (W or kW), source and stated conditions: Scheduled hours: Measured or assumed active fraction: Active hours and operating mode: Standby input, hours and energy: Pre-heat input, hours and energy: Measured energy in kWh, method and test conditions: Calculated kWh where unmeasured: Actual time band: Unit tariff (p/kWh): Unit tariff (£/kWh = p/kWh divided by 100): Energy cost (£ = measured or estimated kWh × £/kWh): Standing charge on the existing account (p/day, record separately): Separate supply or extra charge, if relevant: Open assumptions and follow-up: Actual test-period measured kWh and date (leave blank until measured): EDITABLE WORKED EXAMPLE Replace any assumptions with your own. Examples use one rate. Unit tariff in p/kWh (example 26.32): Divide by 100 for £/kWh (example 0.2632): Heater input (example 1.5 kW): Daily schedule (example 8 h): Keep other loads at 1.152 kWh while isolating heater active time. At active fractions of 25%, 50% and 75%, heating is 3, 6 and 9 kWh. Example totals are 4.152, 7.152 and 10.152 kWh. Multiply by the rate. Raw daily energy costs × workdays in the period gives each period cost. Round each reported cost after multiplying. TEST ANOTHER ASSUMPTION Change one input at a time. Keep any unchanged assumptions with the entry. Shorter workday: Four scheduled hours at 50% active. Workstation and task light run for half as long. Dehumidifier stays at two hours. Heating electricity 3 kWh. Total 3.727 kWh. Lower heat loss after an insulation change: At the same indoor target, weather and hours, assume 35% heater active time. Keep the other loads unchanged. Heating electricity 4.2 kWh. Total 5.352 kWh. Colder weather: Assume heater active time rises to 75% in the same eight hours. Room, setpoint and other loads stay the same. Heating electricity 9 kWh. Total 10.152 kWh. Changed timer schedule: Assume one less scheduled heating hour at the same 50% active fraction. Comfort and other loads require checking. Heating electricity 5.25 kWh. Total 6.402 kWh. More useful heat per kWh: Keep 6 kWh useful heat. At a fictional period ratio of 3, a heat pump uses 2 kWh before auxiliary loads. Other loads are unchanged. Heating electricity 2 kWh. Total 3.152 kWh. Observed or assumed change, baseline period, comfort and occupied conditions: Own heat-only kWh and cost: Own whole-office kWh and cost: